 The Data Alarm Processor-II (DAP II)
offers the definitive answer for precision environmental control. The DAP-II
control system not only controls and monitors temperature, humidity, airflow, and
cleanliness, it provides component run times, alarm history, and an automatic
self-test of the microprocessor.
All messages are presented in a clear,
vernacular format and sequentially displayed on a backlit, liquid crystal display (LCD). The DAP-II can interface with the Data Aire PC (DAPC) Network and the Data Aire Remote Telecommunication System (DART-200).
Standard Features Operational Features
Diagnostic & Service Features Protective & Safety Features
Programmable Selections Conditions & Data Displayed
Functions Displayed Alarms Displayed
Historical Data Displayed
STANDARD FEATURES
Stand alone panel
service terminals or additional devices are not required for programming or
monitoring functions.
Microprocessor based state-of-the-art technology and reliability in a programmable solid
state control panel. two row, 80 character, backlit, supertwist liquid crystal
display (lcd) information displayed and presented in a format that is easily
viewed and understood.
Smooth keyboard type switches high reliability, flat, sealed switches with tactile feedback.
Forward & backward menu access accelerates programming with flexible operation.
Factory-calibrated temperature & humidity sensors accuracy and consistent regulation, especially in multi-unit application
Menus factory programmed menus that pertain to the type and method of cooling, reheat & humidification
based on the unit components and options.
Multilevel password access control unauthorized changes to settings and system functions.
Database of unit and room conditions historical data that facilitates service, apparatus setup, and fine-tuning
of setpoints.
Programmed settings saved in eeprom memory nonvolatile memory storage so all control settings and operational parameters are
secured indefinitely
even during power outage.
Battery backup for historical data extensive historical data preserved by integral battery backup in case of a power
failure.
Automatic self-test diagnostics affirms the processor and select components are functioning properly at power on
and continuously during operation.
Top of Page
OPERATIONAL FEATURES
Selectable control type
designate a control algorithm (smart logic, pid, or setpoint deviation) that will provide optimum
system performance for the application.
Sequential load activation time and temperature based logic that sequentially starts and stops stages of
cooling and reheat.
Temperature anticipation responds to varying rates of temperature change.
Humidity anticipation modifies the humidity setpoint to diminish excess humidification and dehumidification.
Energy saver (glycol) or auxiliary chilled water operation two types of energy saver systems are available. Supplemental compressor
operations during energy saver mode extends the savings from energy saver by
allowing 1 or 2 compressors to supplement operation as needed when energy saver
alone is not sufficient.
Dehumidification mode lockout inhibits dehumidification if not required for performance.
Automatic compressor rotation periodically rotates the lead/lag sequence to balance compressor run times.
Automatic reheat element rotation rotates the staging sequence to balance the run times of the heating elements.
Chilled water, energy saver & hot water coil flush cycle periodically circulates fluid in the coil to reduce deposit buildup in system.
Compressor short cycle control prevents excessive compressor wear by using restart and anti-cycle limits.
Start time delay programmable time delay staggers the start-up of multiple units to prevent
high power demand peaks.
Automatic or manual restart method for restart after power failure is programmable.
Top of page
DIAGNOSTIC & SERVICE FEATURES
Manual diagnostic program accessible procedures for testing the processor and major system components.
Alarms displayed in order of occurrence sequence with time of occurrence assist in diagnosing the cause of alarms.
Manual override for blower, cool 1 & 2, heat 1, humidification & water valve the control circuit is operable even with processor not functioning.
Adjustable alarm limits threshold levels for temperature and humidity alarms are programmable.
Four programmable optional alarms in addition to the standard alarms, there are four programmable alarms available.
Programmable delays for optional alarms deters nuisance and false alarms caused by temporary or transient conditions.
Programmable remote alarm group or specific alarm selection for remote alarm contact.
Select alarms optionally disabled group or specific alarm selection for remote alarm contact.
Select alarms optionally disabled alarms that are nonessential can be turned off.
Audio alarm tone programmable tone pattern for diverse space noise conditions.
Top of page
PROTECTIVE & SAFETY FEATURES
Metal shell enclosure with sealed front control panel electromagnetic interference (em) protection and general protection against
environmental contamination and handling damage.
Isolation transformer protection against ground loops, ground shorts, wiring errors, and conducted
electrical interference.
Opto-coupler signal inputs isolates the circuit board from electrical noise or static from contactors,
compressors, motors, etc., which can contaminate the power at the circuit board.
Protected 24 vac power input fuse, metal oxide varistor (mov), and transient voltage suppressor react
to interrupt the power from the circuit board if excessive amperage or overvoltage condition is detected.
Heavy ground planes & power foils large ground plane areas and wide power runs minimize disturbances caused by emi
and other types of electrical interference.
Watch dog timer automatically resets the circuit board, clears any corrupted memory, and restarts
the system with minimal interruption in case of an unfiltered transient signal.
Switching power supply allows for a wide ac input voltage fluctuation to reduce the effects of a power
brownout while still maintaining circuit board operation.
Fused rs-485 network lines disconnects the circuit board from the source of current to protect the circuit
board components.
Network bypass relays prevents a single unit from disrupting the communication network by automatically
disconnecting the problem unit from the circuit.
Modulating humidifier control * proportional control of steam generator humidifier provides additional refinements
in performance.
Two additional remote alarms * group or specific alarm selection for remote alarm contact.
Humidifier autoflush cycle adjustable flush cycle for infrared and immersion type humidifiers to reduce
deposit buildup.
Analog inputs * output values of two external analog sensors can be read on the processor display.
Rs-485 network system * monitoring and control of 200+ units from a central location with a Data Aire pc network or Data Aire remote telecommunication system. underfloor water
detection cable * provides continuous water detection cable to encircle the
entire data aire unit.
Top of page
PROGRAMMABLE SELECTIONS
Temperature Setpoint
65° - 86° F (18.3° - 29.4° C)
Temperature Deadband ±1° - ±5° F/C
High Temperature Alarm Limit 70° - 90° F (21.1° - 32.2° C)
Disable High Temperature Alarm
Low Temperature Alarm Limit 55° - 75° F (12.8° - 23.9° C)
Disable Low Temperature Alarm
Humidity Setpoint 30% - 70% RH
Humidity Deadband 1.0% - 15.0% RH
High Humidity Alarm Limit 35% - 90% RH
Disable High Humidity Alarm
Low Humidity Alarm Limit 10% - 65% RH
Disable Low Humidity Alarm
Mode & Stage Response Time 1 - 5 Minutes
Compressor Lead/Lag Sequence Automatic
1 Lead
2 Lead
Reset Equipment Runtimes Blower
Condenser
Compressor 1
Compressor 2
Reheat Strip 1
Reheat Strip 2
Reheat Strip 3
Humidifier
Dehumidification
Energy Saver
Chilled Water Cooling
Reset All to Zero Runtimes
Audio Alarm Mode None
Long
Full
Short Beep
Automatic Self-Test Acknowledge On
Off
Manual Diagnostics Stay in Normal Menu Mode
Change to Diagnostic Mode
Humidity Anticipation On
Off
Compressor Short Cycle Alarm On
Off
Compressor Supplements to Energy Saver * Energy Saver not Available
Energy Saver with No Compressors
Energy Saver with 1 Compressor
Energy Saver with 2 Compressors
Dehumidification Mode 1 Compressor within Reheat Limits
2 Compressor within Reheat Limits
1 Compressor with No Reheat Limits
2 Compressor with No Reheat Limits
Dehumidification Off
Low Discharge Temperature Alarm Limit * 45A - 60A F (7.2A - 15.6 A C)
Disable Low Discharge Temperature Alarm
Power Problem or Restart Mode Automatic: No Message or Alarm
Automatic: Message, Audio Alarm & Relay
Manual: Message, Audio Alarm & Relay
Message for Optional Alarm 1, 2, 3, & 4 Custom Message Alarm: 25 Space Message
Fan Motor Overload: Check Motor Amperage * Local Alarm: See Tag Inside Door * Standby Pump On: Check Primary Pump * * UPS/Alternate Power On: Check Main Power * Reheat Inhibited
Humidification Inhibited
Reheat & humidification Inhibited
Delay for Optional Alarm 1, 2, 3, & 4 0 - 900 Seconds
Off
Remote Alarm 1, 2, & 3 Selection * Compressor Short Cycle
Custom Message 1, 2, 3, & 4 * Dirty Filter
Discharge Air Sensor Problem * Fan Motor Overload * Fire Stat
High Humidity
High Pressure Compressor 1
High Pressure Compressor 2
High Temperature
Humidifier Problem
Humidity Sensor Problem
Local Alarm 1, 2, 3, & 4 * Low Humidity
Low Pressure Compressor 1
Low Pressure Compressor 2
Low Temperature
Low Voltage
Maintenance Required
Manual Override
No Airflow
No Water Flow * Power Problem or Restart
Smoke Detector * Standby Pump On * Temperature Sensor Problem
Water Detection Probe
UPS/Alternate Power On
Reheat Inhibited
Humidification Inhibited
Reheat & Humidification Inhibited
Person to Contact on Alarm Contact Message Not Used
Data Processing Manager
Maintenance Engineer
Service Company
25 Space Custom Message
Define Password 00-99
Humidifier Autoflush Timer *
Autoflush Timer Not Used
6 Hours
12 - 96 in 12 Hour Increments
Firestat Temperature Alarm Unit Unit Shutdown & Alarm At: 100° - 150°F
Scheduled Normal Maintenance 1 - 1000 Hours
Off
Temperature Scale Fahrenheit
Centigrade
Control Logic Smart Logic
PID Setpoint Deviation
Unit & Network Identification Number 0 - 260
Calibrate Temperature Sensor + 9.9° F/C
Calibrate Humidity Sensor +30.0% RH
Calibrate Discharge Air Sensor * + 9.9° F/C
Sensor not Installed
Compressor(s) None
Primary
Primary/Secondary
Primary/Primary
Primary/Secondary Primary/Secondary *
Reheat Stages None
1
2
3
Hot Water *
Humidifier None
Computer, Non-Modulating
Computer, Modulating * Comfort, Non-Modulating
Comfort, Modulating *
Water Valve Voltage Range 0 - 10 VDC
4 - 7 VDC
6 - 9 VDC
7 - 10 VDC
Reverse Acting Water Valve Yes
No
Top of page
CONDITIONS & DATA DISPLAYED
Temperature Setpoint
Degrees Fahrenheit or Celsius
Humidity Setpoint
Percent of RH
Current Temperature
Degrees
Current Humidity
Percent of RH
Current Percent of Capacity Utilized Compressor
Reheat
Humidifier
Water Valve
Current Discharge Air Temperature * Degrees
Unit or Network ID # 0 - 260
Zone # 0 - 99
Top of page
FUNCTIONS DISPLAYED
Cooling 1st Stage
2nd Stage
3rd Stage*
4th Stage * Auxiliary Chilled Water Cooling* Energy Saver Cooling *
Reheat 1st Stage
2nd Stage
3rd Stage
Hot Water *
Humidification
Chilled Water Flow 10% - 100%
Dehumidification
Top of page
ALARMS DISPLAYED
High Temperature Warning Current ° F/C
Low Temperature Warning Current ° F/C
High Humidity Warning
Current ° %
Low Humidity Warning Current ° %
High Pressure Compressor 1 Manual Reset Required
High Pressure Compressor 2
Manual Reset Required
Low Pressure Compressor 1 Automatic Reset
Low Pressure Compressor 2 Automatic Reset
Under Floor Water Detection Check Probe
No Air Flow Check Belt & Motor
Dirty Filters Check Filters
Humidifier Failure Check Water Pressure
Manual Override
Check Bypass Switches
Firestat Tripped
Unit Shutdown
Low Voltage Warning
Check Voltage
Power Failure Restart Power Failure or Restart
Compressor Short-Cycle
Warning
Temperature Sensor Error
Sensor Problem
Humidity Sensor Error Sensor Problem
Maintenance Required
Scheduled Maintenance Due
Custom Message
* Up to 40 Character Message
Local Alarm * See Tag Inside Door
Discharge Air Sensor Error * Sensor Problem
Fan Motor Overload * Check Motor Amperage
No Water Flow * Check Water Pump
Smoke Detector * Unit Shutdown
Standby Pump On * Check Primary Water Pump
Person to Contact on Alarm * Up to 25 Character Message
Top of page
HISTORICAL DATA DISPLAYED
Last 24 Hours High & Low Temperature
High & Low Humidity
Average Percent of Capacity Last Hour
Compressor(s) Reheat Stripes
Humidifier
Water Valve
Alarm History Last 10 Alarms
Time Since Occurrence
Equipment Runtimes Blower
Condenser
Compressor 1
Compressor 2
Reheat Strip 1
Reheat Strip 2
Reheat Strip 3
Humidifier
Dehumidification
Energy Saver Cooling * Chilled Water Cooling
*Some of the Optional Features, Programmable Selections, Displays, Alarms
and Historical Data require additional components or sensors. Please contact
your Data Aire Inc. representative for a detailed analysis of your requirements.
Data Aire Inc. reserves the right to make design changes for the purpose of
product improvements, or to withdraw any design without notice.
Top of page |